Difference between revisions of "SYMBiFACE II:Realtime clock"
From CPCWiki - THE Amstrad CPC encyclopedia!
(→See also) |
(→Bugs) |
||
(6 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
This is the documentation about the '''realtime clock''' of the [[SYMBiFACE II]] expansion card. | This is the documentation about the '''realtime clock''' of the [[SYMBiFACE II]] expansion card. | ||
− | + | ||
+ | My (arnoldemu's) SYMBiFACE II uses a Dallas DS12887A. Documents claim this has 128 bytes RAM. Century register doesn't exist. It's ram inside the device. | ||
+ | The picture from the Symbos website shows a DS1287A. This has 50 bytes RAM. Century register doesn't exist. | ||
+ | |||
+ | Both are [[PC compatible RTC chip]] and are programmed in the same way. | ||
+ | |||
+ | Therefore do not rely on a specific amount of RAM inside the RTC chip. | ||
== Ports == | == Ports == | ||
Line 24: | Line 30: | ||
#0C status C see below | #0C status C see below | ||
#0D status D see below | #0D status D see below | ||
− | #32 | + | #32 millennium 19 or 20 (bcd or binary) |
#?? memory all other registers can be freely used as persistent memory | #?? memory all other registers can be freely used as persistent memory | ||
</pre> | </pre> | ||
Line 31: | Line 37: | ||
== Bugs == | == Bugs == | ||
− | * Register 32h is meant to contain the Century (not | + | * Register 32h is meant to contain the Century (not Millennium) |
* Register 32h can be only '''either''' bcd '''or''' binary (not both) | * Register 32h can be only '''either''' bcd '''or''' binary (not both) | ||
* Register 32h documentation does not specify whether it shall be BCD or Binary | * Register 32h documentation does not specify whether it shall be BCD or Binary | ||
− | |||
* Register 32h source code supports only two centuries (19 and 20) this is probably due to misunderstanding the RTC chip datasheet (which sorts of suggests the 8bit RAM location can contain only two different values, which is total nonsense) | * Register 32h source code supports only two centuries (19 and 20) this is probably due to misunderstanding the RTC chip datasheet (which sorts of suggests the 8bit RAM location can contain only two different values, which is total nonsense) | ||
− | * Whether other RAM locations are reserved for whatever purpose (like info about connected 40/80 track drives) is unknown | + | * Whether other RAM locations are reserved for whatever purpose (like info about connected 40/80 track drives) is unknown. See note 1 please. |
* The RAM capacity is 50 bytes: register 0Eh..3Fh (although SYMBiFACE II is incorrectly advertised to have 128 byte persistent RAM) | * The RAM capacity is 50 bytes: register 0Eh..3Fh (although SYMBiFACE II is incorrectly advertised to have 128 byte persistent RAM) | ||
+ | |||
+ | Note 1: In the discmag [[Future View IV]] a proposal is given how to use the non volatile RAM of the SYMBiFACE II and the CPC-Booster+. | ||
== Status registers == | == Status registers == |
Latest revision as of 09:12, 5 April 2019
This is the documentation about the realtime clock of the SYMBiFACE II expansion card.
My (arnoldemu's) SYMBiFACE II uses a Dallas DS12887A. Documents claim this has 128 bytes RAM. Century register doesn't exist. It's ram inside the device. The picture from the Symbos website shows a DS1287A. This has 50 bytes RAM. Century register doesn't exist.
Both are PC compatible RTC chip and are programmed in the same way.
Therefore do not rely on a specific amount of RAM inside the RTC chip.
Ports
- #FD15 (write only) register select
- #FD14 (read/write) read from or write into selected register
Registers
Number Content Values #00 actual second 00-59 (bcd or binary) #01 alarm second 00-59 (bcd or binary) #02 actual minute 00-59 (bcd or binary) #03 alarm minute 00-59 (bcd or binary) #04 actual hour 00-23 (bcd or binary) #05 alarm hour 00-23 (bcd or binary) #06 day of the week ?? #07 day of the month 01-31 (bcd or binary) #08 month 01-12 (bcd or binary) #09 year 00-99 (bcd or binary) #0A status A see below #0B status B see below #0C status C see below #0D status D see below #32 millennium 19 or 20 (bcd or binary) #?? memory all other registers can be freely used as persistent memory
- Note: Register B, Bit 2 allows to select BCD or Binary mode for registers 0..9 (however, this does - of course - not affect RAM location 32h)
Bugs
- Register 32h is meant to contain the Century (not Millennium)
- Register 32h can be only either bcd or binary (not both)
- Register 32h documentation does not specify whether it shall be BCD or Binary
- Register 32h source code supports only two centuries (19 and 20) this is probably due to misunderstanding the RTC chip datasheet (which sorts of suggests the 8bit RAM location can contain only two different values, which is total nonsense)
- Whether other RAM locations are reserved for whatever purpose (like info about connected 40/80 track drives) is unknown. See note 1 please.
- The RAM capacity is 50 bytes: register 0Eh..3Fh (although SYMBiFACE II is incorrectly advertised to have 128 byte persistent RAM)
Note 1: In the discmag Future View IV a proposal is given how to use the non volatile RAM of the SYMBiFACE II and the CPC-Booster+.
Status registers
- Status A
bit0-3 [not used] interrupt frequency bit4-6 time frequency (must be 010; if not, set it to this value, otherwise the RTC will not work correctly) bit7 1 = time is being updated at the moment, so don't read it!
- Status B
bit0 1 = take summer time into account bit1 0 = 12 hours time format, 1 = 24 hours time format bit2 0 = all values in BCD format, 1 = all values in binary format bit3 1 = [not used] activate rectangle generator bit4 1 = [not used] generate interrupt after time update bit5 1 = [not used] generate interrupt if alarm bit6 1 = [not used] generate periodic interrupt (see status A, bit0-3) bit7 1 = stop time update; set this, during you update the time and reset it after the update!
- Status C
bit4 1 = [not used] interrupt has been generated because of time update (see status B, bit4) bit5 1 = [not used] interrupt has been generated because of alarm (see status B, bit5) bit6 1 = [not used] interrupt has been generated because of periodic (see status B, bit6)
- Status D
bit7 0 = battery is nearly empty, please charge or replace
Software
The RTC of the SYMBiFACE II is supported by