Changes
[[RS232 ]] Interface for the CPC by [[Schneider]]. Schneider is the german German distributor for Amstrad CPC hardware (however, thisinterface seems to be was Schneider's own invention, not an [[Amstrad ]] product).
== Pictures ==
Image:Terje Schneider RS232 PCB top.jpg|PCB top
Image:Terje Schneider RS232 PCB bottom.jpg|PCB bottom
Image:Schneider RS232 Interface.jpg|Interface
Image:Schneider-sio-front.jpg|Front Plate
Image:Schneider-sio-label.jpg|Label
Image:Schneider-sio-lead.jpg|Expansion Port Cable
Image:Schneider-sio-psu.jpg|Power Supply
</gallery>
<gallery caption="Schneider RS232 interface 300dpi scans by Robcfg">
Image:Schneider_RS232_Unit.jpg|Interface
Image:Schneider_RS232_Unit_Bottom.jpg|Front Plate
Image:Schneider_RS232_PCB_Top.jpg|PCB Top
Image:Schneider_RS232_PCB_Bottom.jpg|PCB Bottom
</gallery>
Default I/O addresses are F8E0h-F8EFh (though the interface can be jumpered to use different addresses).
F8E0h - [[Z80-STI]] Indirect Data Register F8E1h - [[Z80-STI]] General Purpose I/O Data Register (0=Low, 1=High) F8E2h - [[Z80-STI]] Interrupt Pending Register B (write 0=clear, 1=unchanged) ;\ F8E3h - [[Z80-STI]] Interrupt Pending Register A (write 0=clear, 1=unchanged) ; F8E4h - [[Z80-STI]] Interrupt in-Service Register B ; not used F8E5h - [[Z80-STI]] Interrupt in-Service Register A ; F8E6h - [[Z80-STI]] Interrupt Mask Register B (0=masked, 1=unmasked) ; F8E7h - [[Z80-STI]] Interrupt Mask Register A (0=masked, 1=unmasked) ;/ F8E8h - [[Z80-STI]] Indirect Index and Interrupt Vector Register F8E9h - [[Z80-STI]] Timers A and B Control Register ;\ F8EAh - [[Z80-STI]] Timer B Data Register ; not used F8EBh - [[Z80-STI]] Timer A Data Register ;/ F8ECh - [[Z80-STI]] USART Control Register F8EDh - [[Z80-STI]] Receiver Status Register F8EEh - [[Z80-STI]] Transmitter Status Register F8EFh - [[Z80-STI]] USART Data Register
Aside from the above 16 directly addressable registers, there are 8 indirectly addressable ones. For details on the direct & indirect registers, see [[Z80-STI]].
== Software ==
<gallery>
File:SchneiderSioManualPage4.jpg|Page 4 (blank / footer)
</gallery>
== Note ==
The uncommon shape of the housing dates back to a Schneider BTX modul (which was being intended to be plugged into Schneider Television Sets). Apparently Schneider produced too many housings, and re-used them for the RS232 interface. Actually, a RS232 interface is very much the same as a BTX interface (the actual BTX modem must be rented separately from Deutsche Bundespost), so even the PCB may be (almost/exactly?) the same for both devices.
== Reviews ==
A review appeared in German magazine [[CPC Schneider International]] (issue 12-1985, pages [[Media:Schneider International 8512-p038 - Schneider RS232.jpg|38]], [[Media:Schneider International 8512-p039 - Schneider RS232.jpg|39]]).
== Datasheet ==
* A [[Media:Mostek_3801_Data.pdf|"Z80 STI"]] is a 40pin [[Media:Mostek_3801_Data.pdf|MK3801]] chip from Mostek. Details on that chip are from the "MOSTEK 1982/1983 Microelectronic Data Book" (kindly made available by John Robertson).