765 FDC

2 bytes added, 15 October
/* Motor On/Off Flip-Flop */
Another exception is the Gotek drives. They don't take the motor flip-flop into account and are always on. [https://64nops.wordpress.com/2021/07/04/a-la-decouverte-du-fdc/ Source]
Some FDC commands don't require the motor to be on. For example, the seek or recalibrate commands , that move the floppy drive head , work fine with the motor off. And seek/recalibrate also work with an empty drive (ie. without a floppy disk inserted). [https://64nops.wordpress.com/2021/07/10/a-la-decouverte-du-fdc-episode-2/ Source]
The floppy disk rotates at a nominal speed of 300rpm, with some tolerance. This tolerance of the FDC has been measured by [[Roudoudou]] to be ±12% (it worked from 220 kbits/s to 283 kbits/s for a reference of 250 kbits/s). [https://64nops.wordpress.com/2021/09/02/a-la-decouverte-du-fdc-episode-4/ Source]
8,326