Changes
CRTC
,/* CRTC Differences */
<br>
=== Overflow during HSYNC HSC (C3l) overflow ===
During an HSYNC, if HSYNC Width (R3l) is changed with a value less than the current HSC, then HSC is overflowingoverflows and will continue to count up to its maximum value (15) before looping. The only exception is for CRTC 1 with a value of 0, which cancels the current HSYNC. <br> === VLC (C9) overflow === If Number of Scan Lines (R9) is updated with a value less than the current VLC, then:* on CRTCs 0/1/2, VLC overflows and will count up to its maximum value (31) before looping* on CRTCs 3/4, the current line is considered the last one of this CRTC character and VLC changes to 0 on the next line <br> === VTAC overflow === During vertical adjustment mode, if Vertical Total Adjust (R5) is changed with a value less than the current VTAC, then:* on CRTCs 0/1/2, VTAC overflows and will continue to count up to its maximum value (31) before looping* on CRTCs 3/4, the current line is considered the last one of the current frame and vertical adjustment ends
<br>
=== Overflow during Vertical Adjustment VCC (C4) overflow ===
<br>