Locomotive BASIC

603 bytes added, 19:31, 14 May 2012
/* AFTER ‹time delay›[,‹timer number›] GOSUB ‹line number› */
: In the case of parallel task has 3 the highest and 0 the lowest priority.
: With DI or EI you can disable or enable the timing interrupt. With REMAIN <timer number> you can also disable an AFTER or EVERY construct and stores the "remaining" time (> REMAIN)
: Interrupts run as long as the main loop / program runs, even the main programm is paused > press ESC only '''once''' not twice for a break.
 
<pre>
10 REM > interrupts
20 EVERY 50,0 GOSUB 100: REM > lowest priority
30 EVERY 100,1 GOSUB 200
40 EVERY 200,2 GOSUB 300:
50 AFTER 1000,3 GOSUB 400: REM > highest priority
60 WHILE flag=0
70 a=a+1:print a
80 WEND
90 END
100 REM #0
110 PEN 2:PRINT "timer 0":PEN 1
120 RETURN
200 REM #1
210 PEN 2:PRINT "timer 1":PEN 1
220 RETURN
300 REM #2
310 PEN 2:PRINT "timer 2":PEN 1
320 RETURN
400 REM #3
410 flag=1:PEN 2:PRINT "no more interrupts..."
420 RETURN
</pre>
==== <code>AUTO </code>[‹line number›][<code>,</code>‹increment›] ====
205
edits