* '''Control Register 02h - Interrupt Vector Register Port A (R/W)'''
+
* Control Register 02h - Interrupt Vector Register Port A (R/W)
* '''Control Register 03h - Interrupt Vector Register Port B (R/W)'''
+
* Control Register 03h - Interrupt Vector Register Port B (R/W)
* '''Control Register 04h - Interrupt Vector Register Counter/Timers (R/W)'''
+
* Control Register 04h - Interrupt Vector Register Counter/Timers (R/W)
 
   7-0    Interrupt Vector (Bit3-1 may be automatically modified, see below)
 
   7-0    Interrupt Vector (Bit3-1 may be automatically modified, see below)
 
Port A/B: In Priority Encoded Vector Mode:
 
Port A/B: In Priority Encoded Vector Mode:
 
   3-1    Number of highest Priority Bit with a match
 
   3-1    Number of highest Priority Bit with a match
 
+
Port A/B: In all other Modes:
----
+
 
+
* '''Port A/B: In all other Modes:'''
+
 
   3-1    Bit3-1=All zero if Error, or otherwise Bit3=ORE, Bit2=IRF, Bit1=PMF
 
   3-1    Bit3-1=All zero if Error, or otherwise Bit3=ORE, Bit2=IRF, Bit1=PMF
 
Counter/Timer:
 
Counter/Timer:
Line 190: Line 189:
 
----
 
----
  
* '''Control Register 1Fh - Current Vector Register (R)'''
+
* Control Register 1Fh - Current Vector Register (R)
 
   7-0  Interrupt Vector Based on highest priority unmasked IP (IP=int pending)
 
   7-0  Interrupt Vector Based on highest priority unmasked IP (IP=int pending)
 
         If no interrupt pending then all 1's are output (ie. register is FFh)
 
         If no interrupt pending then all 1's are output (ie. register is FFh)

Latest revision as of 11:36, 19 December 2010


CIO Registers

  • Control Register 00h - Master Interrupt Control Register (R/W)
 7   MIE    Master Interrupt Enable
 6   DLC    Disable Lower Chain
 5   NV     No Vector
 4   PAVIS  Port A Vector Includes Status
 3   PBVIS  Port B Vector Includes Status
 2   CTVIS  Counter/Timers Vector Includes Status
 1          Right Justifies Addresses
             0=Shift Left (A0 from AD1)
             1=Right Justify (A0 from AD0)
 0          Reset (Caution: If set, requires a 3rd write to resurrect)

  • Control Register 01h - Master Configuration Control Register (R/W)
 7   PBE      Port B Enable
 6   CT1E     Counter/Timer 1 Enable
 5   CT2E     Counter/Timer 2 Enable
 4   PCE/CT3E Port C and Counter/Timer 3 Enable
 3   PLC      Port A-and-B Link Control (0=operate independently, 1=linked)
 2   PAE      Port A Enable
 0-1 LC       Counter/Timer Link Controls (see below)

  • Counter/Timer Link Controls values are:
 0=Counter/Timers are Independent
 1=Counter/Timer 1's /OUTPUT does Gate Counter/Timer 2
 2=Counter/Timer 1's /OUTPUT does Trigger Counter/Timer 2
 3=Counter/Timer 1's /OUTPUT is Counter/Timer 2's Count Input

  • Control Register 20h - Port A Mode Specification Register (R/W)
  • Control Register 28h - Port B Mode Specification Register (R/W)
 7-6  PTS Port Type Select (0=Bit Port, 1=Input, 2=Output, 3=Bidirectional)
 5    ITB Interrupt on Two Bytes
 4    SB  Single Buffered Mode
 3    IMO Interrupt on Match Only
 2-1  PMS Pattern Mode Specification (0=None, 1=AND, 2=OR, 3=OR-Priority)
 0    LTM Latch on Pattern Match (in Bit Mode), or
 0    DTE Deskew Timer Enable (in Handshake Modes)

  • Control Register 21h - Port A Handshake Specification Register (R/W)
  • Control Register 29h - Port B Handshake Specification Register (R/W)
 7-6 HTS Handshake Type (0=Interlocked, 1=Strobed, 2=Pulsed, 3=Three-Wire)
 5-3 RWS Request/Wait (0=Request/WAIT Disabled, 1=Output /WAIT, 3=Input /WAIT,
                       4=Special Req, 5=Input Request, 7=Output Request)
 2-0     Deskew Time (MSBs of Deskew Timer Time Constant, LSB is forced 1)

  • Control Register 08h - Port A Command and Status Register (Parts R/W)
  • Control Register 09h - Port B Command and Status Register (Parts R/W)
  • Control Register 0Ah - Counter/Timer 1 Command and Status (Parts R/W)
  • Control Register 0Bh - Counter/Timer 2 Command and Status (Parts R/W)
  • Control Register 0Ch - Counter/Timer 3 Command and Status (Parts R/W)
 7-5     Set/Clear Command       (Write Only) (see command list)
 7   IUS Interrupt Under Service (Read Only)
 6   IE  Interrupt Enable        (Read Only)
 5   IP  Interrupt Pending       (Read Only)
 4   ERR Interrupt Error         (Read Only)

For Port A/B Registers:

 3   ORE Output Register Empty   (Read Only)
 2   IRF Input Register Full     (Read Only)
 1   PMF Pattern Match Flag      (Read Only)
 0   IOE Interrupt on Error

For Counter/Timer Registers:

 3   RCC Read Counter Control    (Read/Set Only - cleared by reading CCR LSB)
 2   GCB Gate Command Bit
 1   TCB Trigger Command Bit     (Write Only) (Read returns 0)
 0   CIP Counter in Progress     (Read Only)

Set/Clear Command List:

 0=Null Code,  1=Clear IP & IUS
 2=Set IUS,    3=Clear IUS
 4=Set IP,     5=Clear IP
 6=Set IE,     7=Clear IE

  • Control Register 22h - Data Path Polarity Register Port A (R/W)
  • Control Register 2Ah - Data Path Polarity Register Port B (R/W)
  • Control Register 05h - Data Path Polarity Register Port C (4 LSBs only) (R/W)
 7-0 DPP Data Path Polarity bits (0=Non-inverting, 1=Inverting)

  • Control Register 23h - Data Direction Register Port A (R/W)
  • Control Register 2Bh - Data Direction Register Port B (R/W)
  • Control Register 06h - Data Direction Register Port C (4 LSBs only) (R/W)
 7-0 DD  Data Direction bits (0=Output Bit, 1=Input Bit)

  • Control Register 24h - Special I/O Control Register Port A (R/W)
  • Control Register 2Ch - Special I/O Control Register Port B (R/W)
  • Control Register 07h - Special I/O Control Register Port C (4 LSBs only)(R/W)
 7-0 SIO Special Input/Output bits (0=Normal Input or Output,
         1=Output with open drain, or Input with 1's catcher)

  • Control Register 0Dh - Port Data Register Port A (R/W) (directly addressable)
  • Control Register 0Eh - Port Data Register Port B (R/W) (directly addressable)
 7-0     Data Bits7-0 (usually 0=Low, 1=High, unless Polarity is inverted)

  • Control Register 0Fh - Port Data Register Port C (R/W) (directly addressable)
 7-4     Lock Bits3-0 (0=Writing Enabled, 1=Writing Inhibited)(Read returns 1)
 3-0     Data Bits3-0 (usually 0=Low, 1=High, unless Polarity is inverted)

  • Control Register 25h - Port A Pattern Polarity (PP) Register (R/W)
  • Control Register 26h - Port A Pattern Transition (PT) Register (R/W)
  • Control Register 27h - Port A Pattern Mask (PM) Register (R/W)
  • Control Register 2Dh - Port B Pattern Polarity (PP) Register (R/W)
  • Control Register 2Eh - Port B Pattern Transition (PT) Register (R/W)
  • Control Register 2Fh - Port B Pattern Mask (PM) Register (R/W)
 7-0  Pattern Bits (PP/PT/PM for Pattern Polarity/Transition/Mask accordingly)

Possible combinations of the PP/PT/PM Bits are:

 PM PT PP Pattern Specification
 0  0  x  Bit Masked Off
 0  1  x  Any Transition
 1  0  0  Zero
 1  0  1  One
 1  1  0  One-to-Zero Transition (falling edge)
 1  1  1  Zero-to-One Transition (raising edge)

  • Control Register 1Ch - Counter/Timer 1 Mode Specification (R/W)
  • Control Register 1Dh - Counter/Timer 2 Mode Specification (R/W)
  • Control Register 1Eh - Counter/Timer 3 Mode Specification (R/W)
 7   C/SC Continuous/Single Cycle (0=Singe Cycle, 1=Continuous)
 6   EOE  External Output Enable
 5   ECE  External Count Enable
 4   ETE  External Trigger Enable
 3   EGE  External Gate Enable
 2   REB  Retrigger Enable
 1-0 DCS  Output Duty Cycle Select (0=Pulse,1=OneShot,2=SquareWave,3=Reserved)

  • Control Register 10h - Counter/Timer 1 Current Count Register MSB (R)
  • Control Register 11h - Counter/Timer 1 Current Count Register LSB (R)
  • Control Register 12h - Counter/Timer 2 Current Count Register MSB (R)
  • Control Register 13h - Counter/Timer 2 Current Count Register LSB (R)
  • Control Register 14h - Counter/Timer 3 Current Count Register MSB (R)
  • Control Register 15h - Counter/Timer 3 Current Count Register LSB (R)
 7-0 CCR Current Count Register (Read Only) (8bits of 16bit total)

  • Control Register 16h - Counter/Timer 1 Time Constant Register MSB (R/W)
  • Control Register 17h - Counter/Timer 1 Time Constant Register LSB (R/W)
  • Control Register 18h - Counter/Timer 2 Time Constant Register MSB (R/W)
  • Control Register 19h - Counter/Timer 2 Time Constant Register LSB (R/W)
  • Control Register 1Ah - Counter/Timer 3 Time Constant Register MSB (R/W)
  • Control Register 1Bh - Counter/Timer 3 Time Constant Register LSB (R/W)
 7-0 TCR Time Constant Register (aka Reload value) (8bits of 16bit total)

  • Control Register 02h - Interrupt Vector Register Port A (R/W)
  • Control Register 03h - Interrupt Vector Register Port B (R/W)
  • Control Register 04h - Interrupt Vector Register Counter/Timers (R/W)
 7-0    Interrupt Vector (Bit3-1 may be automatically modified, see below)

Port A/B: In Priority Encoded Vector Mode:

 3-1    Number of highest Priority Bit with a match

Port A/B: In all other Modes:

 3-1    Bit3-1=All zero if Error, or otherwise Bit3=ORE, Bit2=IRF, Bit1=PMF

Counter/Timer:

 3      Not auto-modified
 2-1    Counter/Timer Number (0=C/T3, 1=C/T2, 2=C/T1, 3=Error)

  • Control Register 1Fh - Current Vector Register (R)
 7-0   Interrupt Vector Based on highest priority unmasked IP (IP=int pending)
       If no interrupt pending then all 1's are output (ie. register is FFh)