Changes

765 FDC

16 bytes added, 7 June
/* FDC Command Table */
== FDC Command Table ==
Command Parameters Exm Result Description 02+MF+SK HU TR HD ?? SZ NM GP SL <R> S0 S1 S2 TR HD NM SZ read track 03 XX YY - specify spd/dma 04 HU - S3 sense drive state 05+MT+MF HU TR HD SC SZ LS GP SL <W> S0 S1 S2 TR HD LS SZ write sector(s) 06+MT+MF+SK HU TR HD SC SZ LS GP SL <R> S0 S1 S2 TR HD LS SZ read sector(s) 07 HU - recalib.seek TP=0 08 - - S0 TP sense int.state 09+MT+MF HU TR HD SC SZ LS GP SL <W> S0 S1 S2 TR HD LS SZ wr deleted sec(s) 0A+MF HU - S0 S1 S2 TR HD LS SZ read ID 0C+MT+MF+SK HU TR HD SC SZ LS GP SL <R> S0 S1 S2 TR HD LS SZ rd deleted sec(s) 0D+MF HU SZ NM GP FB <W> S0 S1 S2 TR HD LS SZ format track 0F HU TP - seek track n 11+MT+MF+SK HU TR HD SC SZ LS GP SL <W> S0 S1 S2 TR HD LS SZ scan equal 19+MT+MF+SK HU TR HD SC SZ LS GP SL <W> S0 S1 S2 TR HD LS SZ scan low or equal 1D+MT+MF+SK HU TR HD SC SZ LS GP SL <W> S0 S1 S2 TR HD LS SZ scan high or eq.
Parameter bits that can be specified in some Command Bytes are:
5,160
edits