Changes

Jump to: navigation, search

SP0256 Measured Timings

34 bytes added, 16:29, 16 January 2010
/* Allophone Lengths */
* min/avg/max = Timings measured on real hardware (Amstrad SSA-1)
The min/avg/max values are slightly higher than the calculated values. This is probably because the SP0256 executes "NOPs" (with repeat=1 and pitch=unchanged) while in standby mode, and refuses to start a new allophone until it has finished the "NOP".
 
[[File:SP0256 SBY Duration.png]]
num name spec calc min avg max
6,388
edits