Serial RS232 Mouse

6 bytes added, 23:45, 8 January 2010
/* Mouse Systems Serial Mouse (rare) */
Normally, the detection response consist of a single character (usually "M"), though some mice have the "M" followed by 11 additional characters of garbage or version information (these extra characters have bit6=0, so after detection, one should ignore all characters until receiving the first data character with bit6=1).
== Mouse Systems Serial Mouse (quite rare) ==
Accessed at 1200 bauds, just like standard serial mouse, but with 8N1 instead 7N1, and with different data bytes.
6,388